? Used for bottom sub-plate mounting ? Installation face follow DIN 24340 D and ISO 5781 ? Used in oil path block installation ? Four pressure ranges ? Four adjustment types: knob, adjustment screw with protection cap, lockable knob with scale, knob with scale ? Optional one directional valve
Fluid
Mineral oil suitable for NBR and FKM seal
Phosphate ester for FKM seal
Fluid temperature range
℃
-30 to +80 (NBR seals)
-20 to +80 (FKM seals)
Viscosity range
mm2/s
10 to 800
Degree of contamination
Maximum permissible degree of fluid contamination: Class 9. NAS 1638 or 20/18/15, ISO4406
Max. operating pressure
Port A, B, X
bar
315
Port Y
bar
315
Setting pressure
Max.
bar
50; 100; 200; 315
Min.
bar
Related with flow-rate(Refer to the characteristic curve)