? Used for bottom sub-plate mounting ? Installation face follow DIN24340 D and ISO5781 ? Used in oil path block installation ? Used in screw connection ? Five pressure ranges ? Four adjustment types: knob, adjustment screw with protection cap, lockable knob with scale, knob with scale ? Optional one directional valve ( only used for bottom sub-plate mounting )
Fluid
Mineral oil suitable for NBR and FKM seal
Phosphate ester for FKM seal
Fluid temperature range
℃
-30 to +80 (NBR seals)
-20 to +80(FKM seals)
Viscosity range
mm2/s
10 to 800
Degree of contamination
Maximum permissible degree of fluid contamination: Class 9. NAS 1638 or 20/18/15, ISO4406
Max. operating pressure
Port B
bar
350
Operating pressure range
Port A
bar
10 to 350
Max.backing pressure
Port Y
bar
350 (only for without check valve);
315 (with check valve)
Setting pressure
Max.
bar
50;100;200;315;350
Min.
bar
Related with flow-rate(Refer to the characteristic curve)