General |
Design | Spool valve, direct operated, with steel sleeve |
Actuation | Proportional solenoid with position control, OBE |
Connection type | Subplate mounting, porting pattern according to ISO 4401-03-02-0-05 |
Installation position | Any |
Ambient temperature range | ℃ | -20...+50 |
Weight | Kg | about 2.75 |
Maximum vibration resistance (test condition) | Max. 25 g, space vibration test in all directions (24h) |
Hydraulic (measured at p=100bar, with HLP46 at ?oil = 40℃ ±5℃) |
Pressure fluid | Mineral oil (HL, HLP)to DIN 51 524 |
Viscosity range | recommended | mm2/s | 20...100 |
max. permitted | mm2/s | 10...800 |
Pressure fluid temperature range | ℃ | -20 to +70 |
Maximum permitted degree of contamination of pressure fluid Purity class to ISO 4406 (c) | Class 18/16/13 |
Rated flow (Δp = 35 bar per edge) | L/min | 2 | 4 | 12 | 24 | 40 |
Max. operating pressure | bar | Port A、B、P:315 |
Max. pressure | bar | Port T: 250 |
|
Leakage flow at 100 bar | Linear | cm3/min | <150 | <180 | <300 | <500 | <900; |
Nonlinear | cm3/min | / | / | / | <300 | <450; |
Static/Dynamic |
Hysteresis | % | ≤0.2 |
Actuating time for signal step 0 ... 100% | ms | 10 |
Temperature drift | Zero shift < 1% at ΔT=40℃ |
Zero compensation | Ex factory ±1% |
Electric, control electronics integrated in the valve |
Relative duty cycle | % | 100ED |
Degree of protection | IP65 |
Connection | Plug-in connector 6P+PE, DIN 43563 |
Supply voltage Terminal A Terminal B
| 24VDCnom |
min. 21VDC / max. 40VDC |
0V (ripple max. 2) |
Fuse protection, external | AF | 2.5 |
nput, version "A1"
Terminal D (UE) Terminal E
| Differential amplifier, Ri = 100 kΩ |
0...±10V |
0V |
Input, version "F1"
Terminal D (ID-E)
Terminal E (ID-E) | Load, Rsh = 200 Ω |
4...12...20mA |
Current loop ID-E return |
Test signal, version "A1"
Terminal F (UTest) Terminal C | LVDT |
0...±10V |
Reference 0 V |
Test signal, version "F1" Terminal F ( I F-C ) Terminal C ( I F-C ) | LVDT signal 4 ... (12) ... 20 mA on external load 200 ... 500 Ωmaximum |
4 ... (12) ... 20mA (output) |
Current loop IF-C return |
Adjustment | Calibrated before delivery, see characteristic curves |